42 lines
1.8 KiB
Markdown
42 lines
1.8 KiB
Markdown
# Heliox communication protocol
|
|
|
|
The following structure can be used to communicate with the Heliox control over several carrier protocols (UART, BL LE,...)
|
|
|
|
## Basic data structure
|
|
|
|
The following table describes the bit pattern for a successful communication with and between Heliox devices.
|
|
|
|
| 0x0 | 0x1 | 0x2 | 0x3 | 0x4 | ... |
|
|
| --- | --- | -------- | ------ | --------- | --------------- |
|
|
| H | X | _length_ | _mode_ | _submode_ | _optional data_ |
|
|
|
|
## Modes
|
|
|
|
### Mode selection
|
|
|
|
The columns represent modes and the rows represent submodes:
|
|
|
|
| | 0x0 | 0x1 | 0x2 | 0x3 |
|
|
| :---: | :---------: | :---------------: | :---------------: | :-------------------------: |
|
|
| | **Message** | **Settings** | **Light control** | **Basic commands** |
|
|
| 0x0 | light data | set baud rate | on | request light data |
|
|
| 0x1 | info | set WIFI password | off | enter console flashing mode |
|
|
| 0x2 | warning | set WIFI SSID | toggle | exit console flashing mode |
|
|
| 0x3 | error | | increase | pair Bluetooth |
|
|
| 0x4 | success | | decrease | help |
|
|
| 0x5 | | | | version |
|
|
|
|
### Optional data
|
|
|
|
Every submode can take any number of Bytes except the below-mentioned ones:
|
|
|
|
| **0 Bytes** | **1 Byte** |
|
|
| :------------: | :--------: |
|
|
| on | increase |
|
|
| off | decrease |
|
|
| flash console | toggle |
|
|
| pair Bluetooth | |
|
|
|
|
### Additional information
|
|
|
|
The maximum length of a message ist 255 Bytes excluding the magic number "BM" and the length slot itself.
|